Status Reporting C-3
GX2-LM1000E* Installation and Operation Manual
RF Parameter Init Major
Alarm
RF Parameter Init
Alarm
Red The lookup table for RF parameters failed to
initiate.
Power Meter Table Init
Major Alarm
Power Meter Table Init
Alarm
Red The lookup table for RF power meter failed to
initiate.
Attenuator Table Init
Major Alarm
Attenuator Table Init
Alarm
Red The lookup table for pin attenuator failed to initiate.
Flash Error Major Alarm Flash Alarm Red Fails to erase or program alternate flash bank.
Flash No Alarm None Green Flash returns to working order.
Laser Data CRC Major
Alarm
Laser Data CRC Alarm Red Fails to verify stored laser data. Module will not
operate.
Factory Data CRC
Minor Alarm
Factory Data CRC
Alarm
Yellow Fails to verify stored factory data (i.e. serial
number).
Alarm Data CRC Major
Alarm
Alarm Data CRC Alarm Red Fails to verify stored alarm limits. Alarm reporting is
stopped.
Reset To Factory
Default
None Green User selected to reset parameters to factory
defaults.