English Locomotive decoders 30s series
Page 40
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Determines the function
buttons to be switched off at
the function defined in
CV#121.
Numerical value*
F1 1
F2 2
F3 4
Switching off
functions at
speed level 0
(LD-G-31,
LD-G-33,
LD-G-34 and
LD-W-33 only)
123 59 0...15
(0)
F4 8
Optimising the
load control
124 61 1...15
(LD-G-30: 3)
(LD-G-31: 9)
(LD-G-32: 2)
(LD-G-33: 2)
(LD-G-34: 2)
To adjust the load control to
the individual motor voltage.
See "optimizing the driving
characteristics" at the end of
section 8., as well.
The value for CV#124 has to be altered when the velocity does not increase with
the high speed levels. Alter the value for CV#124 step by step until the highest
velocity has just been reached at the highest speed level.
Auxiliary
register for
programming
with MM
central units
--- 62 0...64
(0)
To enable the input of values
> 80 with central units
allowing the input of values
between 0 and 80 only.
The value set in register #62 multiplyed by 4 is added to the value of the
register to be programmed. Example for inputting the value 137 into register
#09:
1. 137 / 4 = 34, remainder 1
2. Programming for register #62 the value 34.
3. Programming for register #09 the value 1.