English Locomotive decoders 30s series
Page 12
KI: The integral component of the load control ensures the remaining
difference between the set and the present value is reduced to 0 and so
for the correction of very small divergences. If the set value is too high
the locomotive vibrates massively while moving.
KD: The differential component of the load control ensures that the control
is not converted too quickly. Is the set value to low then the locomotive
vibrates. If the set value is too high, the locomotive shakes while moving.
Velocity characteristic
The decoders can be adjusted to the driving characteristics of the
motor and the characteristic speed of the locomotive type, by setting the
starting velocity and the maximum velocity. From the starting velocity and
the maximum velocity the decoder generates a linear velocity characteristic.
When the speed level mode is set to 28 speed levels, it is possible to
assign any motor voltage to all of the 28 speed levels as an alternative
to the linear velocity characteristic. This allows the programming of a
velocity characteristic which adjusts the individual driving characteristics
of the motor. The set values are saved in the alternative velocity table.
Shunting gear
It is possible to switch into the shunting gear mode via a function key,
when so programmed. In the shunting gear mode, the velocity of all
speed levels is reduced to approx. 50 % compared to the set velocity.
Acceleration and brake delay
It is possible to program the acceleration and brake delay individually
via the central unit. When so programmed, it can be switched on and off
with the function key F3.
Emergency stop
It is possible to carry out an emergeny stop at a change of direction
automatically, when so programmed.
Komentáře k této Příručce