4 - 8 MC319Z RFID Mobile Computer Integrator Guide
Singulation
Select Menu > Config > Singulation to view/configure the singulation control settings for each antenna.
Figure 4-8
Singulation Control Settings Window
This window includes the following fields:
Antenna ID - Selecting an antenna ID updates the configuration values in the other fields.
Session - The session number for the inventory operation.
Tag Population - The approximate tag population in the RF field of the antenna.
Tag Transit Time - The time in milliseconds that the tag typically remains in the RF field of the antenna.
State Aware - Indicates if the antenna performs state aware or state unaware singulation.
Inventory State - Select a tag of state A or B. Valid only for State Aware singulation
SL Flag - Valid only for State Aware singulation
Apply - Select to apply the configuration changes.