D - 4 Omnii Hand-Held with Windows CE 6.0 User Manual
SE965 Scanner
Parameter SE965
Dimensions 0.46 in. H x 0.85 in. W x 0.61 in. D
11.75 mm H x 21.6 mm W x 15.5 mm D
Weight 0.27 oz./7.6 g
Configuration Decoded
Interface SSI Control over TTL Serial on a 12-pin ZIF connector
Scan Angle Wide (default): 47 ° (typical)
Medium: 35° (typical)
Narrow: 10° (typical)
Note: The SE965 scan engine does not require margin on either
side of the barcode to decode. The 47° scan line provides identical
scanning performance to older scan engines with a scan line of 53°.
Skew Tolerance ± 40° from normal
Pitch Tolerance ± 65° from normal
Roll Tolerance ± 35° from vertical
Specular Dead Zone ± 8°
Optical Resolution 0.005 in. minimum element width
Scan Repetition Rate 104 (± 12) scans/sec (bidirectional)
Print Contrast Minimum 25% absolute dark/light reflectance measured at 650 nm
Ambient Lighting Toler-
ance
Tolerant to typical artificial indoor and natural outdoor (direct
sunlight) lighting conditions. Fluorescent, Incandescent, Mercury
Vapor, Sodium Vapor, LED
5
. 450 Ft Candles (4,844 Lux) Sunlight
8000 Ft Candles (86,111 Lux)
Operating Temperature -22° F to 140° F/ -30° C to 60° C
Storage Temperature -40° F to 158° F/ -40° C to 70° C